Schneider Electric · Air Circuit Breaker

MasterPact NW Air Circuit Breaker

High-current ACB family covering 800–6300 A in two principal frame sizes.

This page supports range identification and project communication. Confirm the complete catalog number against the nameplate, ratings, poles, mounting, trip or control unit and auxiliary circuits.

MasterPact NW — Schneider Electric
800–6300 A
Rated current
3P / 4P
Poles
Fixed / drawout
Mounting
MicroLogic 2.0 / 5.0 / 6.0; A / P / H families
Control units

PRODUCT OVERVIEW

MasterPact NW

High-current ACB family covering 800–6300 A in two principal frame sizes.

MasterPact NW covers standard and high-breaking applications. Current code, performance class, pole count, mounting form and MicroLogic unit should all be read from the complete designation or nameplate.

  • Rated current800–6300 A
  • Poles3P / 4P
  • MountingFixed / drawout
  • Control unitsMicroLogic 2.0 / 5.0 / 6.0; A / P / H families

PLATFORM STRUCTURE AND REVIEW POINTS

MasterPact NW — Schneider Electric
  1. 01

    Range architecture

    NW08–NW40 (800–4000 A); NW40b / NW50 / NW63 (4000–6300 A)

  2. 02

    Breaking and withstand performance

    NW08–NW40: N1 / H1 / H2 / H3 / L1 / H10; up to 150 kA at 415/440 V, rating-dependent;NW40b / NW50 / NW63: H1 / H2; up to 150 kA at 415/440 V

  3. 03

    Poles and mounting

    3P / 4P;Fixed / drawout

  4. 04

    Trip and control systems

    MicroLogic 2.0 / 5.0 / 6.0; A / P / H families

TECHNICAL OVERVIEW

Product range
MasterPact NW
Rated current
800–6300 A
Poles
3P / 4P
Mounting
Fixed / drawout
Control units
MicroLogic 2.0 / 5.0 / 6.0; A / P / H families
Frames / branches
NW08–NW40 (800–4000 A); NW40b / NW50 / NW63 (4000–6300 A)

INQUIRY CHECKLIST

  • Complete designation and nameplate
  • System voltage and frequency
  • Rated current and breaking duty
  • Poles and connection arrangement
  • Fixed or drawout mounting
  • Trip or control unit
  • Auxiliary voltage and accessories
  • Quantity and application duty

APPLICATIONS

Industrial manufacturing facility

Industrial and process manufacturing

Main-distribution or critical-feeder protection for manufacturing and process facilities.

Commercial buildings and data centers

Commercial buildings and data centers

Low-voltage distribution where uptime and maintenance efficiency are important.

Power and public infrastructure

Power and public infrastructure

Distribution applications in energy, water, transport and large public facilities.

Renewable-energy infrastructure

Renewable energy and infrastructure

Confirm applicability against AC or DC system data, grounding arrangement and project duty.

RECOMMENDED SERIES RANGES

NW08–NW40

800–4000 A

Breaking / withstand
N1 / H1 / H2 / H3 / L1 / H10; up to 150 kA at 415/440 V, rating-dependent
Poles
3P / 4P
Mounting
Fixed / drawout
Trip / control unit
MicroLogic 2.0 / 5.0 / 6.0; A / P / H families

NW40b / NW50 / NW63

4000–6300 A

Breaking / withstand
H1 / H2; up to 150 kA at 415/440 V
Poles
3P / 4P
Mounting
Fixed / drawout
Trip / control unit
MicroLogic 2.0 / 5.0 / 6.0; A / P / H families

These values identify the range. Confirm final configuration and full ordering information against the nameplate, system data, mounting, cradle interfaces and auxiliary circuits.