ZHIQI ELECTRIC志奇电气

Schneider Electric · Air Circuit Breaker

MasterPact UR Air Circuit Breaker

Ultra-fast current-limiting ACB platform for 5000 A and 6000 A high short-circuit applications.

This page supports range identification and project communication. Confirm the complete catalog number against the nameplate, ratings, poles, mounting, trip or control unit and auxiliary circuits.

MasterPact UR — Schneider Electric
5000 / 6000 A
Rated current
3P
Poles
Drawout only
Mounting
MicroLogic + UR control + UR power
Control system

PRODUCT OVERVIEW

MasterPact UR

Ultra-fast current-limiting ACB platform for 5000 A and 6000 A high short-circuit applications.

MasterPact UR combines a MicroLogic control unit with a dedicated UR control and energy module for ultra-fast operation. It is a project-engineered solution rather than a direct substitute for a standard ACB.

  • Rated current5000 / 6000 A
  • Poles3P
  • MountingDrawout only
  • Control systemMicroLogic + UR control + UR power

PLATFORM STRUCTURE AND REVIEW POINTS

MasterPact UR — Schneider Electric
  1. 01

    Range architecture

    UR50 (5000 A); UR60 (6000 A)

  2. 02

    Breaking and withstand performance

    UR50: 150 kA at 440 Vac; 100 kA at 690 Vac;UR60: 150 kA at 440 Vac; 100 kA at 690 Vac

  3. 03

    Poles and mounting

    3P;Drawout only

  4. 04

    Trip and control systems

    MicroLogic + UR control + UR power

TECHNICAL OVERVIEW

Product range
MasterPact UR
Rated current
5000 / 6000 A
Poles
3P
Mounting
Drawout only
Control system
MicroLogic + UR control + UR power
Frames / branches
UR50 (5000 A); UR60 (6000 A)

INQUIRY CHECKLIST

  • Complete designation and nameplate
  • System voltage and frequency
  • Rated current and breaking duty
  • Poles and connection arrangement
  • Fixed or drawout mounting
  • Trip or control unit
  • Auxiliary voltage and accessories
  • Quantity and application duty

APPLICATIONS

Industrial manufacturing facility

Industrial and process manufacturing

Main-distribution or critical-feeder protection for manufacturing and process facilities.

Commercial buildings and data centers

Commercial buildings and data centers

Low-voltage distribution where uptime and maintenance efficiency are important.

Power and public infrastructure

Power and public infrastructure

Distribution applications in energy, water, transport and large public facilities.

Renewable-energy infrastructure

Renewable energy and infrastructure

Confirm applicability against AC or DC system data, grounding arrangement and project duty.

RECOMMENDED SERIES RANGES

UR50

5000 A

Breaking / withstand
150 kA at 440 Vac; 100 kA at 690 Vac
Poles
3P
Mounting
Drawout only
Trip / control unit
MicroLogic + UR control + UR power

UR60

6000 A

Breaking / withstand
150 kA at 440 Vac; 100 kA at 690 Vac
Poles
3P
Mounting
Drawout only
Trip / control unit
MicroLogic + UR control + UR power

These values identify the range. Confirm final configuration and full ordering information against the nameplate, system data, mounting, cradle interfaces and auxiliary circuits.