Legacy Altivar Platforms — Schneider Electric
Per the earlier catalog
Power range
Per the earlier system
Input voltage
1
Platform branches
0
Representative models

PRODUCT OVERVIEW

Legacy Altivar Platforms

Identification and replacement guidance for legacy Altivar platforms; no direct substitutes are inferred.

The page retains the platform branches and representative commercial references so engineers can continue the review against motor and project conditions.

  • Motor and loadProcess loads
  • ConstructionEnclosed
  • Communication and functionsLegacy platform
  • ApplicationsHigh-power industrial drives

PLATFORM STRUCTURE AND CORE CAPABILITIES

Legacy Altivar Platforms — Schneider Electric
  1. 01

    Power and voltage platform

    Per the earlier catalog;Per the earlier system

  2. 02

    Motor control and duty

    Process loads

  3. 03

    Construction and enclosure

    Enclosed

  4. 04

    Communications, safety and functions

    Legacy platform

TECHNICAL DATA AND PLATFORM BRANCHES

Altivar Plus Drive

Power range
Per the earlier catalog
Input voltage
Per the earlier system
Motor / type
Process loads
Construction
Enclosed
Communication & functions
Legacy platform
Applications
High-power industrial drives

LEGACY PLATFORM REVIEW

19 original platforms and replacement directions

Use this table for identification and inquiry preparation only; it does not imply a one-for-one replacement.

Original rangeOriginal useReview directionMust verify
Altivar 08Earlier compact driveATV12Re-verify motor current, mounting dimensions and I/O
Altivar 11Low-power simple machinesATV12Not a one-to-one mechanical-size replacement
Altivar 16 / 18Early compact driveATV12 or ATV320Re-select by function and motor current
Altivar 21Earlier HVAC driveATV212 or ATH600Confirm the BMS protocol and harmonic characteristics
Altivar 31 / 31CMachine drive in the 0.18-15 kW classATV320; ATV12 may be considered for simple loadsRe-verify I/O, braking, communication and dimensions
Altivar 312Classic machine driveATV320Communication cards, logic functions and parameters cannot be copied directly
Altivar 312 SolarEarlier PV pumping driveAltivar SolarRecompute the PV array voltage and pump curve
Altivar 32Machine driveATV320Verify safety functions, communication and mounting dimensions
Altivar 58Earlier industrial driveATV900/ATV340, depending on the loadRe-select by constant-torque, closed-loop and braking requirements
Altivar 61Pump/fan and variable-torqueATV600 or ATH600Confirm process communication, bypass, harmonics and protection degree
ATV61 Plus / Plus-LH / QHigh-power enclosed, low-harmonic or water-cooledATV660/680 or an ATV600 engineered systemRequires project-specific replacement; do not size by power alone
Altivar 66 / 68Earlier industrial driveATV900/ATV600Re-select according to load type
Altivar 71High-performance heavy dutyATV900 or ATV340Re-verify encoder, braking, safety and communication
ATV71 Plus / Plus-LH / QHigh-power enclosed, low-harmonic or water-cooledATV960/980 or an ATV900 engineered systemRequires project-specific replacement
ATV303Simple machines, 0.37-11 kWATV305/ATV310/ATV320Select by country of sale, function and price tier
ATV212Classic HVAC, 0.75-75 kWATH600 (for new projects)Verify BMS, EMC, protection and harmonic functions
Altivar Field DriveEarlier outdoor drive systemAltivar Outdoor DriveRe-engineer based on the underlying VFD, enclosure and bypass configuration
Altivar Plus DriveEarlier enclosed drive systemAltivar Process Drive SystemsRe-engineer by input, output, harmonics, bypass and cooling
Altivar LiftLift dedicatedProject-specific replacementConfirm the traction machine, encoder, brake and safety standards

INQUIRY CHECKLIST

  • Complete designation and nameplate
  • Input voltage and phases
  • Motor power and rated current
  • Heavy- or normal-duty profile
  • Mounting and enclosure rating
  • Braking and safety functions
  • Communication protocols and options
  • Quantity, environment and application

RANGE SUMMARY

Product range
Legacy Altivar Platforms
Power range
Per the earlier catalog
Input voltage
Per the earlier system
Motor / type
Process loads
Construction
Enclosed

APPLICATIONS

Pumps, fans and compressors

Pumps, fans and compressors

Size the drive against load profile, speed range, continuous duty and energy objectives.

Machines and material handling

Machines and material handling

Match motor type, dynamic response, braking, safety and fieldbus requirements.

Process industries

Process industries

Confirm environment, enclosure, communications, bypass and asset-management requirements.

Retrofit and infrastructure

Retrofit and infrastructure

Begin with the existing drive nameplate, motor data, interfaces and installation space.

RECOMMENDED PLATFORM RANGES

Altivar Plus Drive

Per the earlier catalog

Input voltage
Per the earlier system
Applications
High-power industrial drives

This is a range overview, not a complete selection result. Verify the final configuration against the full catalog number, motor, supply, duty, installation environment, communications and safety requirements.