ZHIQI ELECTRIC志奇电气

Schneider Electric · Vacuum Circuit Breaker

Evolis Vacuum Circuit Breaker

Indoor three-pole VCB family up to 24 kV for fixed or cradle-based integration.

Evolis is retained as its own identification family. Exact ratings and cradle compatibility must be checked against the complete equipment designation.

Evolis — Schneider Electric
Up to 24 kV
Rated voltage
3P
Poles
Fixed / cradle-based
Mounting
Nameplate, cradle and switchgear interface
Verification

PRODUCT OVERVIEW

Evolis

Indoor three-pole VCB family up to 24 kV for fixed or cradle-based integration.

Evolis is retained as its own identification family. Exact ratings and cradle compatibility must be checked against the complete equipment designation.

  • Rated voltageUp to 24 kV
  • Poles3P
  • MountingFixed / cradle-based
  • VerificationNameplate, cradle and switchgear interface

PLATFORM BRANCHES AND REVIEW POINTS

Evolis — Schneider Electric
  1. 01

    Evolis

    Use the complete nameplate for replacement matching.

  2. 02

    Rating-range review

    Rated voltage, current and breaking duty must be checked within the same technical branch and never combined across branches.

  3. 03

    Mounting and switchgear interface

    Confirm fixed or withdrawable construction, primary interface, phase distance and cradle against the actual switchgear.

  4. 04

    Auxiliary circuits and interlocking

    Review auxiliary voltage, coils, charging mechanism, secondary plug and interlocking with the project documentation.

TECHNICAL OVERVIEW

Product family
Evolis
Rated voltage
Up to 24 kV
Rated current
Per exact designation
Breaking / withstand
Per exact designation
Poles
3P
Mounting / structure
Fixed / withdrawable with cradle

INQUIRY CHECKLIST

  • Complete product nameplate
  • System rated voltage
  • Rated current
  • Breaking / withstand duty
  • Fixed or withdrawable arrangement
  • Switchgear and primary interface
  • Auxiliary and control voltage
  • Application duty and operating cycle

APPLICATIONS

Industrial manufacturing

Industrial manufacturing

Medium-voltage feeder and equipment protection in manufacturing and process industries.

Commercial and critical facilities

Commercial and critical facilities

For commercial buildings and critical infrastructure requiring dependable MV distribution.

Power systems and infrastructure

Power systems and infrastructure

MV switchgear for substations, transport and public infrastructure.

Water and renewable energy

Water and renewable energy

MV distribution projects in water, renewable energy and related infrastructure.

RECOMMENDED SERIES RANGES

Evolis — Schneider Electric

Evolis

Up to 24 kV

Rated current
Per exact designation
Breaking / withstand
Per exact designation
Poles
3P
Mounting / structure
Fixed / withdrawable with cradle

These values identify the range. Confirm final configuration and full ordering information against the nameplate, system data, mounting, switchgear and auxiliary circuits.

Message on WhatsApp