ZHIQI ELECTRIC志奇电气

Schneider Electric · Vacuum Circuit Breaker

VR Vacuum Circuit Breaker

Horizontal drawout VCB family up to 27 kV for Masterclad MV switchgear.

VR is selected together with the Masterclad switchgear version and ANSI ratings. Voltage class, current, interrupting rating and cradle/interface details are all essential.

VR — Schneider Electric
Up to 27 kV
Rated voltage
5–15 kV commonly 1200–4000 A
Rated current
5–15 kV commonly 25–63 kA
Breaking current
3P horizontal drawout
Structure

PRODUCT OVERVIEW

VR

Horizontal drawout VCB family up to 27 kV for Masterclad MV switchgear.

VR is selected together with the Masterclad switchgear version and ANSI ratings. Voltage class, current, interrupting rating and cradle/interface details are all essential.

  • Rated voltageUp to 27 kV
  • Rated current5–15 kV commonly 1200–4000 A
  • Breaking current5–15 kV commonly 25–63 kA
  • Structure3P horizontal drawout

PLATFORM BRANCHES AND REVIEW POINTS

VR — Schneider Electric
  1. 01

    VR

    Verify the exact switchgear version and ANSI rating set.

  2. 02

    Rating-range review

    Rated voltage, current and breaking duty must be checked within the same technical branch and never combined across branches.

  3. 03

    Mounting and switchgear interface

    Confirm fixed or withdrawable construction, primary interface, phase distance and cradle against the actual switchgear.

  4. 04

    Auxiliary circuits and interlocking

    Review auxiliary voltage, coils, charging mechanism, secondary plug and interlocking with the project documentation.

TECHNICAL OVERVIEW

Product family
VR
Rated voltage
Up to 27 kV
Rated current
5–15 kV commonly 1200–4000 A
Breaking / withstand
5–15 kV commonly 25–63 kA
Poles
3P
Mounting / structure
Horizontal drawout for Masterclad

INQUIRY CHECKLIST

  • Complete product nameplate
  • System rated voltage
  • Rated current
  • Breaking / withstand duty
  • Fixed or withdrawable arrangement
  • Switchgear and primary interface
  • Auxiliary and control voltage
  • Application duty and operating cycle

APPLICATIONS

Industrial manufacturing

Industrial manufacturing

Medium-voltage feeder and equipment protection in manufacturing and process industries.

Commercial and critical facilities

Commercial and critical facilities

For commercial buildings and critical infrastructure requiring dependable MV distribution.

Power systems and infrastructure

Power systems and infrastructure

MV switchgear for substations, transport and public infrastructure.

Water and renewable energy

Water and renewable energy

MV distribution projects in water, renewable energy and related infrastructure.

RECOMMENDED SERIES RANGES

VR — Schneider Electric

VR

Up to 27 kV

Rated current
5–15 kV commonly 1200–4000 A
Breaking / withstand
5–15 kV commonly 25–63 kA
Poles
3P
Mounting / structure
Horizontal drawout for Masterclad

These values identify the range. Confirm final configuration and full ordering information against the nameplate, system data, mounting, switchgear and auxiliary circuits.

Message on WhatsApp