ZHIQI ELECTRIC志奇电气

SIEMENS · SENTRON SERIES

SENTRON 3WA1 Air Circuit Breaker

A high-reliability platform for power distribution and industrial applications

SENTRON 3WA1 air circuit breakers protect low-voltage incomers, bus couplers and high-current feeders. Three frame sizes cover a broad rating range, with electronic protection, metering and communications configured to the project.

  • High breaking capacityFor main distribution and high fault levels
  • System protectionSupports selectivity and withstand studies
  • Modular designSimplifies installation, options and service
  • Digital integrationSupports metering, status and industrial networks
Siemens SENTRON 3WA1 official air circuit breaker family image
AC 630–6300 ARated current
DC up to 4000 ADC application
IEC up to 690 V ACRated voltage
55–150 kA @ 500 V ACIcu
3P / 4PPoles
Fixed / withdrawableMounting

PRODUCT ARCHITECTURE

A modular architecture for diverse applications

Three frames, electronic trip units and fixed or withdrawable mounting cover incomers, bus couplers and high-current feeders.

01

3WA1 FRAME

Frame I

A compact frame for standard main-distribution duties.

Mounting
Fixed / withdrawable
Poles
3P / 4P
02

3WA1 FRAME

Frame II

For higher-capacity distribution and bus-coupler duties with metering and connectivity options.

Mounting
Fixed / withdrawable
Poles
3P / 4P
03

3WA1 FRAME

Frame III

For the upper current range and high-breaking-capacity applications.

Mounting
Fixed / withdrawable
Poles
3P / 4P

TECHNICAL DATA

Core technical range

Use these published 3WA1 ranges for early project definition. Confirm final ratings against the complete designation and duty.

Rated current (AC)
630–6300 A
DC application
Up to 4000 A
Rated operational voltage
IEC up to 690 V AC
Ultimate short-circuit breaking capacity (Icu)
55–150 kA @ 500 V AC
Poles
3P / 4P
Mounting
Fixed / withdrawable
Electronic trip units
ETU300 / ETU600
Connectivity
PROFINET IO · Modbus TCP / RTU

TRIP UNITS & CONNECTIVITY

Intelligent protection and open connectivity

Select the trip unit and connectivity package from the required protection, metering and system-integration scope.

01

ETU300 electronic trip unit

For core protection duties; confirm L/S/I/G functions from the complete configuration.

02

ETU600 electronic trip unit

Supports extended protection, metering, diagnostics and system integration.

03

Connectivity and integration

PROFINET IO and Modbus TCP / RTU options are available; confirm the required modules per project.

INSTALLATION & ACCESSORIES

Flexible installation and practical service

Coordinate fixed or withdrawable construction and accessories with panel design, operation and maintenance strategy.

01

Fixed mounting

A compact arrangement for standard switchboards.

02

Withdrawable mounting

Supports isolation, testing, maintenance and rapid replacement.

03

Safety and interlocking

Coordinate mechanical, electrical and key interlocks with the panel.

04

Accessory options

Confirm motor operator, coils, auxiliary and position contacts.

SELECTION WORKFLOW

Engineering selection and project workflow

  1. 01

    Requirements

    Define voltage, current, fault level and load duty.

  2. 02

    System design

    Choose frame, poles, mounting and protection scope.

  3. 03

    Technical review

    Confirm Icu, Ics, Icw, trip unit and selectivity.

  4. 04

    Quotation

    Submit configuration, quantity, delivery and destination.

  5. 05

    Delivery

    Confirm accessories, control voltage, wiring and panel interface.

  6. 06

    Operation

    Maintain settings, test results and spare-parts records.

APPLICATIONS

Designed for a wide range of distribution duties

01

Buildings

Commercial, transport and public-facility distribution.

02

Manufacturing

Plant incomers, bus couplers and high-current feeders.

03

Data centers

Critical power distribution and selective protection.

04

Energy and utilities

Generation, distribution and utility systems.

05

Infrastructure

Ports, airports, rail and municipal projects.

06

Other industries

Water, chemical, metals and process facilities.

RFQ CHECKLIST

Information required for quotation

Provide these details for faster configuration review.

  • Project and applicationDefines the system duty
  • Current and voltageAC / DC and frequency
  • Breaking requirementsIcu, Ics and Icw
  • MountingFixed or withdrawable
  • Poles and neutral3P / 4P
  • Trip unitETU300 / ETU600
  • CommunicationsPROFINET or Modbus
  • Accessories and interlocksCoils, contacts and interlocks
  • Quantity and deliveryTarget date and quantity
Message on WhatsApp